CyberResearch UMDAS 0802DA Manual de usuario Pagina 16

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 20
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 15
DATA ACQUISITION
143
Toll-Free Assistance: 1
-
800
-
341
-
2525
(
USA
)
Tel: 203
-
643
-
5000 Fax: 203
-
643
-
5001
www.cyberresearch.com
Applications Engineers: Monday Friday, 9:00 AM 5:00PM, U.S. Eastern Time • e-mail: [email protected] Visit our website for detailed product information!
& Addressable Ethernet to Remote Intelligent DAQ Line
For Comparison Charts, see pages 144
~
147
Customer requests have per-
suaded us to add more than 30 new
C
YMOD 7000 remote modular DAS
modules to our lineup! Now match-
ing a module to the detailed require-
ments of your application is much
easier than it ever has been.
Our CyMOD CM 7000 series is
an enhancement to our 4000 series
modules. Our popular CYMOD
4000 and ADAM 4000 models
remain available.
New A/D, D/A & DIO Lines
Our line of CYMOD analog input
models now includes two new
8-input models, expanded thermo-
couple and RTD ranges, plus
expanded strain-gauge support.
There are two new analog-output
modules with programmable
power-on values & output slopes.
Twelve new digital I/O modules
have inputs that can also be used
as 16-bit counters, outputs that
support up to 100 mA per channel
(or relays for AC power), and LEDs
that show I/O and relay status.
Ethernet, USB, & Serial Converters
We’ve also added 8 converter
modules (pages 144-145). Isolated
serial converters and repeaters
help mix & match RS-232/422/485
signals. You can place up to 256
modules on one RS-485 twisted
pair without a repeater or as many
as 2,048 modules with repeaters.
CM 7188 Ethernet to serial
converter modules include one to
seven RS-232 ports. They can
assign a unique address to each
RS-232 device. That means your
PC can both send a command to a
specific RS-232 device and receive
a response back from it.
Advanced CYMOD 7000 Features
Selected features of our new
CYMOD 7000 series include:
Up to 5000 V
RMS
isolation voltage &
overvoltage protection to ±240V.
Faster A/D modules offer 16-bit
resolution at 10 S/s or 12 100 S/s.
Free DASYLab
®
& ActiveX
drivers,
plus OCX, DDE, and DLL libraries.
Powered from 10~30V
DC.
Industry Standard Compatibility
All CYMOD and ADAM modules
can be used together. Series 4000
modules perform the same
functions, and are designed to be
both hardware and software-
compatible. CYMOD 7000 modules
closely follow the other two, but
with a newer case design.
All three series are the same
size, and can be wall, DIN-rail, or
piggyback-mounted (on top of each
other) in much the same way. How-
ever, 7000 models and 4000 models
do not piggyback on each other.
All three lines offer signal
conditioning, DAQ, and control.
C
YMOD modules can be seamlessly
integrated into an existing ADAM
system to provide cost savings.
Our new CM ENC06 & CM ENC16
enclosures mount both CYMOD and
ADAM modules.
There can be minor specification
differences between C
YMOD modules
and their ADAM counterparts.
Detailed specs charts on pages
144
~
147 make comparisons easy.
Advanced C
Y
MOD 7000 Modules
Join Tried-and-True C
Y
MOD 4000 Series
Our new CM 7000 series of modules come with
a complete set of DLLs for Win32, Borland
®
C/C++, Delphi
®
, VB5, VC5, DASYLab, ActiveX
(OCX), and DDE Server. Utility software is also
included for Windows
®
98/2000/NT/XP. These
intelligent modules are easily controlled via an
ASCII-format request/reply protocol.
Several software options are available for use
with our CM 4000 series of data-acquisition
modules. Included at no additional cost is
CyberResearch’s CM DLL Windows-compatible
Dynamic Link Library for these modules.
Outstanding features include:
32-bit device drivers to take full advantage
of Windows 95/98/2000/NT/XP
A complete set of Visual C/C++ and Visual
Basic example programs to clarify the use of
each function.
DAQBench is a Windows 95/98/2000/NT/XP 32-bit
library of ActiveX controls for CYMOD 4000
modules that has won praise from users for its
ease of use and intuitive operation. It enables you
to create customized data acquisition programs by
simply dragging and dropping objects.
• Useful user-interface controls and controls for
digital, analog, and timing I/O operations
• An Analysis Library featuring a complete set
of analysis functions to help you convert your
raw data into meaningful results
For detailed information, please visit our website.
#PCI DAQB DAQBench for CYMOD 4000 Series.......$Call
Complete Software Support
for C
Y
MOD & ADAM Modules
RS-485 Repeater Isolated USB to
RS-232/422/485
Converter
Ethernet to
RS-232/485
Converter
RS-485 USB
Ethernet
RTD
mV
V
mA
Thermocouple
mV
V
mA
Input Input Input
Output OutputOutput
Relay
Output
Digital
I/O
Analog
Output
Powered from
110/220 V
AC;
our CM 243 provides
24V
DC @3A (72W).
CYMOD 7000 RS-485 Multidrop Network
Product datasheets
available at our website
start where the others
leave off! Whatever
technical details you
might be looking for
about any of our C
YMOD
or ADAM modules be it ones presented through-
out this section or ones unique to our website
you’ll find them all at cyberresearch.com.
Need ALL the Details?
Visit www.cyberresearch.com!
Remote Industrial Ethernet DIO
IPDIO 7060
IPDIO 7060
Now you can control
remote real-life industrial
equipment via Ethernet or
over the internet using
our IPDIO 7060 DIO
module. Each module has
a built-in web server with
its own IP address, so you
can log in and monitor or
control the module from
anywhere in the world!
See pg. 153
for details
142-143.06$ 12/27/10 3:16 PM Page 2
Vista de pagina 15
1 2 ... 11 12 13 14 15 16 17 18 19 20

Comentarios a estos manuales

Sin comentarios